Honeywell HCU-2000 Intevio Controller
The HCU-2000 controller is the core unit of Honeywell’s Intevio PAVA systems. It effortlessly performs multiple critical functions like audio storage and playback, signal processing, zone control, routing, scheduled broadcasts, supervision and fault detection. It meets international standards for safety. With its built-in 500W Class-D amplifier, this single controller can work as an integrated, 8-zone PAVA system for better stability, cost savings and superb user experience.
Description
The controller integrates multiple functions such as audio storage, playback, zone control, audio monitoring, scheduled broadcast, fault diagnosis, and a lot more.
Honeywell’s HCU-2000 Master Control Unit has a powerful automatic fault diagnosis function to supervise various types of faults such as main power, backup power, CPU, microphone, power amplifier, speaker circuits, and dry contact inputs. All the fault information will be displayed on the LED indicators and LCD screen, and the fault logs will be kept in the internal memory.
Even if the CPU of the controller malfunctions, the INTEVIO system still allows the user to deliver paging to all the zones with the PTT microphone or the call station. HCU-2000 also enables users to record temporary messages to its built-in 1GB memory with the PTT microphone or the call station and broadcast it without configuration.
Features:
- A highly compact and integrated system
- Simple and easy-to-use, plug and play with default settings
- Provides easy access to status updates, amplifier backup, logging, and direct paging capabilities Highly efficient solution
- Intuitive set-up with step-by-step guided interaction between buttons and screens
- Can achieve all calls by configurable keys
- Auto configures when components are physically connected
- Integrated voice alarm and public address system controller with built-in 500W amplifier
- Has numerous user-friendly functions to increase operation efficiency: record and play, mobile APP control, the interaction between LCD and buttons, etc.
- Save on total ownership cost by implanting recorder, timer, audio monitor, and one for all backup amplifier solution
- Complies with international standards
Additional information
Weight | 17.4 kg |
---|---|
Dimensions | 48.2 × 13.35 × 42 cm |
Technical Specifications
Backup power supply voltage | ~ 220V-240V 50/60Hz |
Power consumption | <720W |
Main power supply fuse | T10AH 250V |
Amplifier output | 70V / 100V |
Rated output power | 500W |
Frequency response | 80Hz~18KHz (+1dB ~ – 3dB) |
Input impedance | 20KΩ |
Input sensitivity | (RJ-45) 1.4V |
Aux. input 1 | 1.4V |
Aux. input 2 | 100V |
Main power supply voltage | AC 220-240V, 50/60Hz |
Backup power supply voltage | AC 220-240V, 50/60Hz |
Main power supply fuse | T10AH 250V |
Rated power | 750W |
Input sensitivity | -65±3dBV |
Input impedance | 250Ω |
Frequency response | 90 Hz -13KHz |
SNR | >50dB (with A-Weight) |
Channels | 2 |
Input sensitivity | 1V (0dBV) |
Input impedance | 10 KΩ |
Frequency response | 85Hz-18KHz |
SNR | >77dB (with A-Weight) |
Input sensitivity | -50dBV/0dBV, selectable |
Input impedance | 10 KΩ |
Frequency response | 85Hz-18KHz |
SNR | >77dB (with A-Weight) |
Phantom power | DC 24V, switchable |